Device not powered: neither Power supply, nor Battery, RESET
Pre-Commission Mode / Overtravel detected in Normal mode, no 24V
AC GSI blinks mostly ON or OFF
AC GSI indicating LUET – Teach in Mode – Normal Mode
Normal Mode -- NGL Powered
Normal Mode – UET active, in door zone, Door Safety bridged
Overspeed – Teach In > 1m/s, ETSL detects overspeed at
Hoistway end , reset automatic done after 10 sec.
1.) Emergency Mode internally
2.) Emergency Mode, Unintended Car Movement in door zone (UCM)
3.) Normal Mode but MX-Battery Powered
blinks mostly ON --Pre commissioned no floors learned
blinks mostly OFF –”Teach IN Mode KNE Contact closed
A and B used for access to different SALSIS Modes.