N. STEP (only programs “TIME”)
A number of heating steps (or cooling steps) can be set:
- 1 ÷ 10
STEP 1
(only programs “TIME”)
For each step composing the cycle, it is possible to decide the drying temperature and the step length:
- TIME: 1’ ÷ 120’
- TEMPERATURE: 0°C ÷ 90°C
STEP 2 … 10
For each step composing the cycle, it is possible to decide the drying temperature and the step length:
- TIME: 1’ ÷ 120’
- TEMPERATURE: 0°C ÷ 90°C
COOLING TIME
It corresponds to the length of the cooling cycle at the end of the drying cycle. This time is automatically reduced if the set point cooling temperature is reached before the end of the cycle:
- 0’ ÷ 30’
COOLING TEMPERATURE SET POINT
It is the cooling temperature which determine the end of the drying program. If the cooling time elapse before the temperature is reached, the program end however.
- 0°C ÷ 90°C
REVERSING DRUM (with machine with reversing options)
In case the machine is equipped with a reversing option, this function can be excluded from the program.
If the parameter “WITHOUT” is selected, the drum
turn always in the same direction (right).
- WITH
- WITHOUT
DRUM RIGHT ROTATION TIME (machines and programs WITH REVERSING DRUM)
It is the drum clockwise turning time:
0” ÷ 5’
DRUM STOP TIME
(machines and programs WITH REVERSING DRUM)
It is the drum rotation pause:
1” ÷ 5’
DRUM LEFT ROTATION TIME (machines and programs WITH REVERSING DRUM)
It is the drum counterclockwise turning time: