Usually the polyethylene particles (product) settle in the settling leg and are removed
through the product takeoff valve. Occasionally, the product plugs the settling leg, and the plug is removed by maintenance personnel. The normal - and safe - procedure includes closing the
DEMCO valve, removing the air lines, and locking the valve in the closed position. Then the
product takeoff valve is removed to give access to the plugged leg.